Turnkey automatic room extinguishing system

Fire Eater delivers turnkey room extinguishing systems with Inergen – so-called ARS systems. Where personal safety is concerned, Inergen systems are among the safest room extinguishing systems to be found on the market.

As well as not causing damage to equipment or buildings when activated, Inergen particularly stands apart from other extinguishing methods when it comes to personal safety and sustainability.

The extinguishing method itself is based on oxygen displacement. This means in concrete terms that the oxygen content in the room where Inergen is released is lowered from approx. 20.9% to a level around between 12 to 14%. The low oxygen level means that there insufficient oxygen to maintain a fire, which is therefore extinguished.

The unique thing about Inergen is that where other extinguishing methods of this type only lower the oxygen level, Inergen contains 8% CO2, meaning that the body (brain and muscles) can better absorb such oxygen as there is during activation of the ARS system. This is what makes this solution safe for people.

Inergen is sustainable in that it wholly consists of naturally occurring gases that are in the atmosphere (nitrogen 52%, argon 40% and carbon dioxide 8%). This means that there is no impact on the environment when a system is activated. Nor are any chemicals used. Inergen consequently has zero greenhouse effect and zero impact on the ozone layer. You could say we borrow existing gases, use them to put out a fire and deliver them back in exactly the same condition.

Watch the 3D Fire Eater film about how Inergen works.

A turnkey Inergen solution

  • A control panel

  • One or more detection units

  • An activator button

  • Alarm units

  • Pressurised cylinders with Inergen

  • Pipe system with nozzles

Automatisk rumslukningsanlæg med Inergen

1. The control panel

The control panel is the control unit of an ARS system. The entire process, from activation until the fire is extinguished, is coordinated from this unit. It is self-monitoring and ensures that all bottles of Inergen and all connections in the circuit are well-functioning and ready for use. If it detects a fault which may mean that the system is not fully operational, the control panel sounds an alarm so that the fault can be rectified.

Most error messages can be resolved on the spot using the operating instructions.

Kontrollpanel Automatisk romslukningsanlegg

2. Detection

The purpose of the detection units is rapid discovery of a fire so that it can be extinguished immediately and damage minimized. Using Inergen, a fire is typically extinguished in less than 40 seconds.

Fire Eater recommends that an ARS system include a two-circuit detector solution, where both detectors send a fire-alarm before the system is activated. The total number of detectors needed depends on the size of the room.

The number of detectors we propose is always based on the nature of the room concerned and the requirements as to how quickly a fire must be detected. There are several different options where detection units are concerned.

You can choose between point detection such as optical smoke and/or thermo-detectors or a highly sensitive aspiration system.  In places where very early detection is necessary, we recommend the use of aspiration systems. The detectors also detect fire under an installation floor or above a lowered ceiling.

Detektering i Automatisk romslukningsanlegg

3. Activator button

Activator buttons are typically installed on all escape routes. This allows manual activation of the room extinguishing system. People in the room may thus activate the Inergen system when on their way out the door by pressing the activator button. It is possible for the control panel to send a signal to an ABDL system, ensuring that all doors are automatically closed to keep Inergen inside the room where the fire is.

trykkutløser Automatisk romslukningsanlegg

4. Alarm units

Alarm units provide acoustic and visual alarms that sound and flash when activation is initiated. Such units are placed above access doors to the room where the Inergen fire extinguishing system is installed. The siren makes a pulsing sound for the first 30 seconds; it thereafter changes to a continuous tone. When the sound is continuous, activation of the system itself has started.

We recommend that people leave the room during activation.

Inergen alarmtavle Automatisk romslukningsanlegg

5. Pressurised cylinders with Inergen

The Inergen is stored in pressurised cylinders of varying sizes at below 200 or 300 bar pressure. They may be placed inside the protected room or elsewhere. Most people choose to install the cylinders vertically, but horizontal installation is also possible. This provides great flexibility when installing the system.

A manometer is mounted on top of each cylinder, indicating the pressure therein. This makes it easy to see whether the cylinders are full or empty. Empty cylinder can be easily refilled.

If the pressure in a cylinder drops, the control panel will automatically display an alarm. This ensures that the system is operational at all times.

The cylinders empty upon activation, whether this is triggered manually or if the control panel has detected a fire and subsequently activates the system. For refilling, contact Fire Eater on telephone 4068 2769. We will be there to start refilling no later than 24 hours after receiving notification of an activation.

Inergen-flaske Automatisk romslukningsanlegg

6. Pressure relief damper

When an Inergen system is activated, an overpressure occurs in the protected space. It is important that this overpressure is equalised so that the fire can be extinguished under controlled conditions. It is the job of the pressure relief damper to perform this function. The size and number of pressure relief dampers are adapted to each individual solution.

Inergen trykkavlastningsspjeld Automatisk romslukningsanlegg

7. Pipe system with nozzles

The Inergen is released via nozzles from a pipe system, dispersing it into the protected space. Each pipe system is specially adapted to the individual installation. There are a number of different types of nozzles to choose from, depending on whether they are to be visible or hidden. It is also possible to install nozzle dampers. These are typically used in data centres to protect data upon activation.

Inergen-dyse – Automatisk romslukningsanlegg

We are ready to help…

We hope the above has given you an idea of how an ARS solution works in practice. We are specialists in Inergen extinguishing solutions, and we are always ready to help you along the way. So don’t hesitate to contact us.

    * We treat your data with respect and do not pass it on to third parties. You can request your data be deleted at any time. See our privacy and cookie policy in the menu under "About Fire Eater"

    © Copyright - Fire Eater

    Why Fire Eater?

    Fight fire with Fire Eater

    Fire prevention is your concern, but it’s our expertise. Receive the optimal fire protection system with comprehensive customer support, from system design to maintenance services. With over 40 years of experience with inergen technologies and innovation, we bring hyper-focused knowledge and a proven solution to your data center.

    Our systems are meticulously designed and manufactured to adhere to strict standards, undergoing rigorous testing, and certification processes to ensure compliance with international fire safety regulations. We provide customized solutions that cater to your facility’s unique fire protection requirements, ensuring optimal performance, safety, and seamless integration.

    By selecting Fire Eater, you’re choosing a partner dedicated to providing the tools that make your job easier.

    How it works

    How Inergen systems work in a data center

    The Inergen® fire suppression system is an automated solution designed to swiftly and effectively extinguish fires. It employs an aspiration system, which incorporates highly sensitive fire detection technology capable of identifying fires in their initial stages. Once a fire is detected, Inergen® is promptly released into the room. Reducing the oxygen level just enough to stop combustion, without posing any risk of harm to individuals present.

    Watch the video

    Sustainability

    From fireproof to future-proof

    Choose a sustainable fire suppression system that benefits your business and the environment.

    Inergen is an inert gas that is entirely eco-friendly and sustainable. It is composed of naturally occurring atmospheric gases, including 52% nitrogen, 40% argon, and 8% carbon dioxide.

    Inergen is entirely safe to breathe and has a Global Warming Potential (GWP) and Ozone Depletion Potential (ODP) of zero. Additionally, unlike some fire suppression agents, Inergen leaves no residue and requires no cleanup after discharge. This eliminates the need for extensive cleanup or costly downtime. Making it a cost-effective and future-proof fire suppression system for data centers.

    Why Inergen?

    Extinguish your risk

    Keep people and assets safe with no secondary damage. Inergen® efficiently suppresses fire in just 40 seconds, causing no damage nor harm to people, equipment, or the planet.

    Reasons for inergen fire protection in your data center

    Quick and automated response time.
    Rapid extinguish rate.
    Proven and reliable technology.
    No subsequent re-ignition.
    Harmless to humans.
    Automatic room shut-off system.
    Zero damage to servers, data, and server racks.
    Waterless system.
    100% sustainable.
    No clean up.
    No downtime.