Fire protection of warehouses

Firefighting with Inergen prevents fire and consequential damage

If a fire breaks out in a warehouse, damage to the goods stored may be rapid. Production stops and there is inevitable downtime. It can quickly become very expensive – not just owing to the fire damage itself, but also to the secondary damage, from foam or deluge water for example.

With Inergen, you get a fire extinguishing solution that optimises your storage capacity and extinguishes fire rapidly and efficiently – without consequential damage.

5 good reasons for using Inergen as fire protection in warehouses

  • Early detection of fire.

  • Effective ‘3D extinguishing’ – with minimal risk of re-ignition.

  • Safe to stay in the warehouse when the system is active.

  • No consequential damage to goods and other materials – quick resumption of operations.

  • Optimal utilisation of shelf space and storage height – no distance requirements between nozzles and goods.

Explore our Knowledge Forum

Here you will find answers to why Inergen is the fire extinguishing technology that ensures a greener future.

Continue operations in the warehouse 10 minutes after the fire has been extinguished

Fire protection solution for a warehouse must not only be able to prevent fire damage but also ensure that there is no consequential damage, such as from deluge water or foam.

Inergen consists of 100% natural gases, which are present in the atmosphere. It therefore causes no consequential damage to goods and materials, and, unlike traditional solutions with water and foam, does not leave you with an extensive clean-up job. This means that you can continue operations in a warehouse immediately after an Inergen system has been utilised. Most important of all, however, is that it is safe for employees to be in the warehouse when the Inergen is released into the room.

Why use Inergen for firefighting?

Do you want to know more
about Inergen?

Go to our Knowledge Forum

How Inergen Works in warehouse buildings

A Fire Eater Inergen system uses sensitive detectors that respond automatically to fire. The system releases the Inergen via nozzles that are typically placed in the ceiling. Since there is no minimum distance requirement from nozzles to shelves, you can benefit from utilising the maximum height capacity.

An Inergen system employs ‘3D extinguishing’. This means that the gas – released under pressure –distributes itself throughout the warehouse, under stacks, over shelves, behind and inside cupboards, in electrical panels and even in rubbish bins; even tall stacks up to a certain height can be protected from the ceiling. Nor is there any need for pipes to cover specific shelves. After the Inergen system has been installed, you can alter the lay-out of shelves and corridors at will. The Inergen nozzles do not have to be placed directly above the stacks. This makes the system extremely effective and particularly suitable for warehouse buildings.

Fire Eater A/S firefighting

Which solutions should you choose for fire protection of a warehouse?

Fire Eater has developed a range of special solutions which make it possible to adapt and construct the perfect solution to your specific requirements. The Inergen system offers great flexibility and you can, for example, install the cylinders outside the warehouse itself in a separate room.

We analyse your needs, the building and the size of the warehouse etc., and, on the basis of that information, draw up a proposal for the solution that best matches your requirements. We dimension all systems for the specific storage space or building.

No-obligation advice from specialists

With no obligation to buy, you can receive a review of your specific fire protection requirements and advice on which solution would be best for you. We are also more than happy to prepare an offer.

Get contacted by a fire protection specialist

Fill out the contact form and we will conta

Do you want to know more
about Inergen?

Whether you need advice or a thorough review of your fire protection needs, our team is ready to guide you every step of the way. We can answer all your questions and provide the support you need.

Simply fill out the contact form and we will contact you immediately. Your fire safety is our top priority.

Get in contact.

    * We treat your data with respect and do not pass it on to third parties. You can request your data be deleted at any time. See our privacy and cookie policy in the menu under "About Fire Eater"

    © Copyright - Fire Eater

    Why Fire Eater?

    Fight fire with Fire Eater

    Fire prevention is your concern, but it’s our expertise. Receive the optimal fire protection system with comprehensive customer support, from system design to maintenance services. With over 40 years of experience with inergen technologies and innovation, we bring hyper-focused knowledge and a proven solution to your data center.

    Our systems are meticulously designed and manufactured to adhere to strict standards, undergoing rigorous testing, and certification processes to ensure compliance with international fire safety regulations. We provide customized solutions that cater to your facility’s unique fire protection requirements, ensuring optimal performance, safety, and seamless integration.

    By selecting Fire Eater, you’re choosing a partner dedicated to providing the tools that make your job easier.

    How it works

    How Inergen systems work in a data center

    The Inergen® fire suppression system is an automated solution designed to swiftly and effectively extinguish fires. It employs an aspiration system, which incorporates highly sensitive fire detection technology capable of identifying fires in their initial stages. Once a fire is detected, Inergen® is promptly released into the room. Reducing the oxygen level just enough to stop combustion, without posing any risk of harm to individuals present.

    Watch the video

    Sustainability

    From fireproof to future-proof

    Choose a sustainable fire suppression system that benefits your business and the environment.

    Inergen is an inert gas that is entirely eco-friendly and sustainable. It is composed of naturally occurring atmospheric gases, including 52% nitrogen, 40% argon, and 8% carbon dioxide.

    Inergen is entirely safe to breathe and has a Global Warming Potential (GWP) and Ozone Depletion Potential (ODP) of zero. Additionally, unlike some fire suppression agents, Inergen leaves no residue and requires no cleanup after discharge. This eliminates the need for extensive cleanup or costly downtime. Making it a cost-effective and future-proof fire suppression system for data centers.

    Why Inergen?

    Extinguish your risk

    Keep people and assets safe with no secondary damage. Inergen® efficiently suppresses fire in just 40 seconds, causing no damage nor harm to people, equipment, or the planet.

    Reasons for inergen fire protection in your data center

    Quick and automated response time.
    Rapid extinguish rate.
    Proven and reliable technology.
    No subsequent re-ignition.
    Harmless to humans.
    Automatic room shut-off system.
    Zero damage to servers, data, and server racks.
    Waterless system.
    100% sustainable.
    No clean up.
    No downtime.

    How do you best

    extinguish a fire?

    It depends on many things - and you have several options.